| Utility requirements | |||
| Power: 480 VAC, 30 AMP, 3 Phase, 60 HZ
standard. Other voltages optional. Air: 80 psi, 1 cfm |
|||
| Machine control | |||
| Industrial control group C-128 microprocessor,
Allen-Bradley illuminated push-pull
buttons, digital speed indicator, elapsed time meter, Boston gear SCR DC
drives. (Options: Reliance drive, master reference control.) Emergency stop pull cord around entire machine. Push-pull impression control for each color deck and each plate cylinder deck. Forward/reverse control for drive. Forward and reverse jog push- buttons. Baldwin ink agitators. Driven through air clutch for added safety and ease of plate registration and clean-up. |
|||
| Machine construction | |||
| 1.5-inch precision ground steel frames.
1.5 inch face, 16 diameter pitch, 20 degree pressure angle steel gears. Heat treated, polished, hard chrome plated fountain rolls. Carbon steel plate and blanket cylinders with .002-inch diameter and .0005-inch runout, static balance. Bronze oscillator rolls. Automatic lubrication system with alarm and catch pans for oil. Catwalks supplied around entire machine. Heavy-duty precision-ground bearings. Mounted on jack-screws or casters. |
|||
| Technical Specifications | |||
|
|||